Skip to content
Tuesday, October 13, 2026AboutContactRSS
Vulnerabilities

Siemens Drive Controllers Face Critical Cross-Site Scripting Flaw in CSV Import

A critical vulnerability in Siemens SIMATIC hardware allows attackers to execute code via crafted CSV files imported by authorized users.

Updated with new details.
Illustration: A gray industrial controller sits on a metal workbench with its protective cover removed to reveal exposed circuit boards.
AI-generated illustration: Threat Times

Key points

  • CVE-2026-63354 carries a CVSS score of 9.6, rated as critical severity.
  • The flaw affects specific SIMATIC Drive Controller and ET 200SP CPU models.
  • Attackers can execute JavaScript in a user's browser to perform PLC operations.

Siemens SIMATIC industrial hardware contains a critical cross-site scripting vulnerability that could allow remote attackers to execute arbitrary code. The flaw, tracked as CVE-2026-63354, stems from improper validation of visual marker data within imported CSV trace files.

At a glance

CVE
CVE-2026-63354
Product
Siemens SIMATIC Drive Controller CPU 1504D TF
CVSS
9.6 Critical
Weakness
cross-site scripting
Exploited
No known exploitation

According to the National Vulnerability Database, the issue allows an attacker to inject malicious JavaScript into the Trace page rendering process. This happens because affected devices do not properly sanitize the data before displaying it.

Technical Context and Impact

The vulnerability is classified with a CVSS v3.1 score of 9.6, which places it in the critical severity range. The underlying weakness is identified as CWE-79, which relates to improper neutralization of input during web page generation.

An attacker must first social engineer an authorized user into importing a specially crafted trace file. The user must hold the specific function right known as “Read diagnostics” for the attack to succeed.

Once the malicious file is imported, attacker-controlled JavaScript executes within the victim’s browser session. This code can then perform Programmable Logic Controller (PLC) operations through the web server. The actions performed are limited to the scope of the user’s authorization.

Affected Hardware Models

Several specific Siemens SIMATIC components are affected by this vulnerability. The list includes Drive Controller CPU models and ET 200SP CPU models.

Affected Drive Controller units include the Siemens SIMATIC Drive Controller CPU 1504D TF. The Siemens SIMATIC Drive Controller CPU 1507D TF is also listed as vulnerable.

The ET 200SP series includes multiple vulnerable configurations. The Siemens SIMATIC ET 200SP CPU 1510SP F-1 PN is affected. The Siemens SIMATIC ET 200SP CPU 1510SP-1 PN is also listed.

The source material lists these ET 200SP models twice with slight variations in naming conventions. Both the F-1 PN and the -1 PN variants are included in the affected list.

No specific version numbers are provided for the affected products. The records indicate that versions prior to an unspecified update are vulnerable.

What should you do?

Security teams should immediately audit their environments for the presence of affected Siemens hardware. Identify any systems running the listed Drive Controller or ET 200SP CPU models.

Review access controls for the “Read diagnostics” function right. Limit this permission to only those users who strictly require it for operational tasks.

Monitor network traffic for unusual patterns originating from web servers associated with these controllers. Look for unexpected PLC operations initiated through browser sessions.

Until a confirmed fix is available, restrict the ability to import CSV trace files. Implement strict file validation on endpoints before allowing users to process diagnostic data.

What to do and how to stay safe: Siemens

  • Inventory all Siemens SIMATIC Drive Controller and ET 200SP CPU devices to identify affected models.
  • Restrict the “Read diagnostics” user permission to a minimal number of trusted administrators.
  • Block or monitor the import of CSV trace files on systems running vulnerable hardware versions.
  • Await official vendor guidance and patches for CVE-2026-63354 before restoring full import functionality.

Step-by-step guide: Risk Based Vulnerability Management: Prioritize Fixes by Actual Threat

General security guidance from the Threat Times newsroom. It is not confirmed advice from the organisations named in this story.

Frequently asked questions

What is the CVSS score for CVE-2026-63354?

The vulnerability has a CVSS score of 9.6, which is rated as critical severity.

Which Siemens products are affected by this flaw?

Affected products include SIMATIC Drive Controller CPU 1504D TF, CPU 1507D TF, and several ET 200SP CPU 1510SP models.

How does an attacker exploit this vulnerability?

An attacker social engineers an authorized user to import a crafted CSV trace file, allowing JavaScript execution in the browser.

Sources

  1. CVE Program
SiemensCVE-2026-63354SIMATIC Drive ControllerET 200SPCross-Site Scripting